After-sales Service: | Following Updating |
---|---|
Warranty: | Under Discussion |
Switching Power Supply: | DC24V |
Still deciding? Get samples of US$ 650/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1.Basic weighing transmission function, and includes two preset point output control functions; |
2.Sampling speed up to 960 times/second; |
3.Supports calibration with weights, calibration without weights and calibration of load cell parameters; |
4.Weight indicator can be calibrated through the serial port; |
5.Standard RS485 or RS232 serial port (specify when ordering) and optional analog output; |
6.Support of seven protocols: r-Cont, RS-SP1, Modbus, rECont, rEREAD, Toledo protocol, Cb920 protocol; |
7.Optional DA analog, the output type can be switched by parameters, 4-20mA/0-20mA/0-24mA/0-5V/0-10V; |
8.Optional network port, support Modbus TCP protocol. |
General Specifications | Switching Power Supply | DC24V |
Working Temperature | -10~40ºC | |
Maximum humidity | 90%R.H non-condensing | |
Protection Grade | Front panel IP65 | |
Power Consumption | Approx. 10W | |
Display and keys | Weight display | Single-row LED data display |
Function keys | 4-key audible keypad | |
Overload display | "OFL" | |
LED display | [zero]: zero point;[stab]: Stabilization;[hold]:hold | |
A/D conversion | A/D performance | 24-bit Sigma-Delta |
A/D conversion speed | 120/480/960 times/second adjustable | |
Non-linearity | 0.01%F.S | |
Gain Drift | 10PPM/°C | |
Input Sensitivity | 0.1μV/d | |
Input Range | 0mV~15mV | |
Maximum Display Accuracy | 1/100000 | |
Sensor power supply | DC5V, enough to drive 8 3500 sensors | |
Input Impedance | 10MΩ | |
Zero Adjustment Range | 0.02~15mV | |
I/O section | Inputs | 1 input port, low level active |
Zeroing (pulse signal active)/trigger hold/level active | ||
Outputs | 2 output ports, single drive current 500mA | |
Stabilized/overflow/satisfied setpoint condition outputs | ||
Output interface configuration program | Option 1: RS485 | |
Option 2: RS232 | ||
Option 3: RS485 + analog outputs | ||
Option 4: RS232 + analog output | ||
Option 5: Modbus TCP + RS485 | ||
Option 6: Modbus TCP + RS232 |