After-sales Service: | Following Updating |
---|---|
Warranty: | Under Discussion |
Weighing: | Customizable |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1.Optional resultant force [F] algorithm: 3-D algorithm [F2=X2+Y2+Z2] and CUSUM cumulative sum algorithm [F=X+Y+Z]. |
2.By setting relevant parameters, the X/Y/Z sampling channels can be opened and closed to achieve single channel force measurement, two channel force measurement, and three channel force measurement. |
3.The DO output signal is used for "real-time force alarm" or "peak force alarm". |
4.The overall EMC design has strong anti-interference ability and is suitable for industrial environments. |
5.32-bit ARM CPU, 48MHz main frequency, fast computation speed. |
6.2x16 character LCD display screen with white LED backlight, displaying English characters/numbers. |
7.Adopting a 24 bit high-precision high-speed ∑ - △ A/D conversion module, with an internal resolution of 1/1000000 and a sampling frequency of 1280Hz. |
8.Adopting a unique anti vibration filtering algorithm to ensure the stability and accuracy of force measurement results when the force measuring device vibrates strongly, as well as the ability to quickly respond to changes in force values. |
9.Can connect 8 350 Ω force sensors. |
10.Equipped with zero calibration, load calibration, and digital calibration functions. |
11.Equipped with digital setting, digital calibration, and interface testing functions. |
12.Four normally open switch inputs [DI] and two normally open/normally closed transistor switches [DO] output combined upper/lower limit alarm signals. |
13.RS232 or RS485 communication ports can be used to connect the upper computer IPC/PLC and LED remote display. |
Adopting a multitasking working mode, it does not affect the process of force measurement, alarm output, and signal transmission during parameter setting and other operations. |
Display: |
1.2x16 character LCD display screen with white LED backlight, displaying English characters/numbers. |
2.The display range of force values for X/Y/Z channels is -5000 to+5000. |
3.The display range of the combined force is 0~9999. |
4.Maximum force measurement for X/Y/Z channels: can be set from 1 to 5000. |
5.Display division: optional 1, 2, 5, 10, 20, 50,100,200,500. |
6.Display resolution: 1/5000. |
7.Force units: optional kg, t, g, N, kN, no units. |
8.Decimal position: optional 0, 0.0, 0.00, 0.000. |
9.Display refresh time: can be set to 0.01-1.00s. |
Keys: |
4 buttons for quick operations |
X/Y/Z channel force sensor interface: |
1.Excitation voltage/maximum current: DC5V, 120mA (8 350 Ω force sensors). |
2.Signal input range: ± 35mV. |
3.Output sensitivity of force sensor: 1.0~7.0mV/V. |
4.24 bit ∑ - △ ADC with an internal resolution of 1/1000000. |
5.Sampling frequency: 1280Hz. |
6.Unique anti vibration filtering algorithm, precise force measurement, stable display, and fast response. |
7.Zero drift: ± 0.1 μ V/ºC RTI (equivalent to input). |
8.Gain drift: ± 5ppm/ºC. |
9.Non linearity: 0.005% FS. |
Switching interface: |
1.4-way normally open switch input [DI]. |
2.Two transistor switches [DO] output real-time resultant force or peak/lower limit alarm signals for resultant force. |
3.Transistor switch contacts can be defined as "normally open contacts" or "normally closed contacts". |
4.Transistor switch contact capacity: DC24V, 10mA. |
Digital communication interface: |
1.COM1: Fixed configuration RS485&RS232, choose one of them through internal DIP toggle switch. |
2.Can be connected: upper computer IPC/PLC and LED remote display. |
Work indicators: |
1.Working voltage: DC24V ± 20%. |
2.Maximum power consumption: 5W. |
3.External dimensions: 107 x 60 x 100mm (width x height x depth). |
4.Disk opening size: 94 x 47mm (width x height). |
5.Working temperature: -10 ºC~+40 ºC. |
6.Storage temperature: -30 ºC~+60 ºC. |
7.Relative humidity: not exceeding 85% RH. |
8.Front panel protection level: IP65. |
9.Weight: Approximately 0.25kg. |