• Sm40-32FC Flow Totalizer Flow Measurement
  • Sm40-32FC Flow Totalizer Flow Measurement
  • Sm40-32FC Flow Totalizer Flow Measurement
  • Sm40-32FC Flow Totalizer Flow Measurement
  • Sm40-32FC Flow Totalizer Flow Measurement
  • Sm40-32FC Flow Totalizer Flow Measurement

Sm40-32FC Flow Totalizer Flow Measurement

After-sales Service: Following Updating
Warranty: Under Discussion
Transport Package: Wooden Box
Specification: 152*76
Trademark: Sun-Moon
Origin: China
Samples:
US$ 10/Piece 1 Piece(Min.Order)
| Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Rating: 5.0/5
Anhui, China
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
100% Finished Products Inspection
The supplier inspects 100% of finished products.
R&D Capabilities
The supplier has 3 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (20)

Basic Info.

Model NO.
SM40-32FC
HS Code
9031809090
Production Capacity
30000PCS/Year

Product Description

Basic specifications

Project specifications

Power supply voltage AC power supply V0 100-240 V AC 50/60 Hz

AC/DC power supply V1 10-24V AC 50/60 Hz; 10-24V DC

Power consumption of AC power supply below 8 VA

AC/DC power supply AC: below 7 VA; DC: Below 6W

The allowable voltage variation range is 90%~110% of the power supply voltage

Insulation resistance ≥ 100M Ω (500V DC MEGA reference)

Insulation strength 2000V AC (test conditions: 50/60Hz, 1 minute)

Anti interference IEC61000-4-2 (electrostatic discharge), Class III

IEC61000-4-4 (Electrical Fast Transient Pulse Group), Class III

IEC61000-4-5 (surge), Class III

Protection level IP65 (product front panel protection) (GB/T42-2008)

Operating environment temperature -10~55 ºC (storage: -25~65 ºC)

Environmental humidity of 35-85% R • H, no condensation

Installation location indoor, height < 2000m

Input specifications

Project specifications

Measure and control speed for 0.6 seconds

Basic error ± 0.2% F • S

Display range -99999~99999

Flow input signal IK DC current (4-20) mA, (0-10) mA, (0-20) mA and pulse input 0.1Hz~5kHz

VK DC voltage (0-5) V, (1-5) V and pulse input 0.1Hz~5kHz

MK millivolts (0-100) mV and pulse input 0.1Hz~5kHz

Temperature input signal R thermistor: Pt100, CU100, CU50

I DC current (4-20) mA, (0-10) mA, (0-20) mA

E Thermocouple: K, T, E, S (0~999.9) ºC

Pressure input signal I DC current (4-20) mA, (0-10) mA, (0-20) mA

V DC voltage (0-5) V, (1-5) V

M millivolts (0-100) mV
Output specifications

Project specifications

External power supply

(Pressure channel power supply) B1 24V ± 5%, below 50mA

B2 12V ± 5%, below 50mA

External power supply

(Power supply through flow channel) B1 24V ± 5%, below 50mA

B2 12V ± 5%, below 50mA

Optional specifications

Project specifications

Alarm output T1~T2 1-2 points relay preset output, 250V AC/3A, resistive load

Analog output

(Resolution: 1/3000) A1 current output (4-20) mA, (0-10) mA, (0-20) mA

A2 voltage output (1-5) V, (0-5) V

A3 voltage output (0-10) V

Communication interface S1 RS232 interface, TC ASCII protocol

S2 RS485 interface, TC ASCII protocol

M1 RS232 interface, Modbus RTU protocol

M2 RS485 interface, Modbus RTU protocol

USB Dump Interface USB USB Dump