After-sales Service: | Following Updating |
---|---|
Warranty: | Under Discussion |
Switching Power Supply: | AC90~260V 50Hz(60hzplus and Minus2% |
Still deciding? Get samples of US$ 650/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1.Dual scales feeding control, working modes such as hopper/no hopper/bulk material totalization; |
2.Feeding control, bag tapping, dunnage bag, discharging vibration; |
3.Batch number setting and total amount of shipment setting function; |
4.Dual serial port communication function, two sets of independent parameters, can be the same; |
5.Communication and connection to printer at the same time; |
6.Serial connection to the GM8897 touch screen; |
7.Flow statistics and display function (bulk material totalization mode); |
8.Simulation function, which is convenient for on-site equipment debugging; |
9.Quick modification of recipe parameters during operation; |
10.Software update through computer; |
11.Rich IO ports, including 12 switch inputs and 16 switch outputs, in addition to meeting its own packaging needs, some can be reserved for backup, and through the switch definition to define the port, which can solve the situation of some port abnormalities, burned out, not working; |
12.10 groups of formula storage function, convenient for customers to store and switch the packaging parameters of different kinds of materials with different specifications; |
13.two 24-bit high-precision AD data acquisition module, a single meter can realize the packaging process of double scales, the meter has a logic interlock function, simplify the circuit design of the electronic control cabinet, reduce the failure points; |
14.The working mode is divided into: with measuring hopper, without measuring hopper, bulk, the user used to be able to configure this parameter according to their own process requirements or the mechanical structure of the scale to meet the needs of adaptive applications, such as bulk scales, then select the bulk mode can be; |
15.automatic three-speed control, and large, medium and small can be used in combination or independent output, which can simplify the customer's electrical diagram design and to achieve a variety of control modes, and can be material speed to improve the speed and accuracy of the packaging (later upgraded to four-speed); |
16.Feeding control function, through the setting of the upper and lower material level, can realize the automatic replenishment function of the feeding equipment, so as to ensure that the material in the feeding hopper is balanced and maintained at a certain warehouse pressure, to improve the accuracy of the packaging (later upgraded to three material level control); |
General Specifications | Switching Power Supply | AC90~260V 50Hz(60Hz)±2% |
Operating Temperature | -10~40ºC | |
Maximum humidity | 90%R.H non-condensing | |
Protection Grade | Front panel IP65 | |
Power Consumption | Approx. 25W | |
A/D Conversion | A/D Performance | 24-bit Sigma-Delta |
A/D conversion speed | 120/240 times/second | |
Non-linearity | 0.01%F.S | |
Gain Drift | 10PPM/°C | |
Input Sensitivity | 0.5uV/d | |
Input Range | 0. 2 to 27mV (2mV/V for sensor) | |
Maximum Display Accuracy | 1/30000 | |
Sensor Power Supply | DC12V Single drive for 8 350Ω sensors | |
Input Impedance | 10MΩ | |
Zero Adjustment Range | 0.2~20mV (when sensor is 2mV/V) | |
I/O section | Inputs | 12 inputs, active low |
Start/Emergency stop/A,B scale zero/clear alarm/A,B scale manual under throw/Recipe selection/Keypad lock/Up and down level/Printing/Level start/A,B scale level manual under throw/Stop/Clip bag in place/A,B scale manual dosing, level manual dosing/Mid level/A,B scale dosing door closed in place signal/A,B scale unloading door open in place/Enter input from sewing machine for manual unloading of A,B scales( binyES, bULK) / Clip, Loose Bag Request (binyES) / A,B Scale Clip, Loose Bag (binno) / Clogging Input (Bulk) / Manual Unloading of A,B Scale Levels (binyES, Bulk)/A,B scale discharge door closed in place (binyES, Bulk)/B scale clamp, bag in place, loose bag (binno)/manual discharge (bULK)/tank up, tank down level (bULK)/loose bag in place (binyES)/A,B loose bag in place (binno) |
||
Outputs | 16 output ports, single drive current 500mA | |
Running / A,B scale large, medium, small cast / A,B scale fixed value, unloading / overrun / stop / lack of material / supply / A,B scale zero zone, cut-off output, oversized cast / last scale / serial port controllable switching / A,B scale feeding stepper motor pulse output, feeding stepper motor direction of rotation signals / A,B scale unloading closed door, feeding open door, feeding closed door / A,B unloading stepper motor pulse output, unloading stepper motor rotation direction signal / sewing machine output / thread cutter output bag clamping (binyES) / A,B scale bag clamping (binno) / bag patting (binyES) / A,B scale bag patting (binno) / batch completion (binyESbinno) / shipment completion (bULK) / conveyor output (binno) / A,B scale unloading vibration (binyES, Bulk) / Discharge (bULK) / Coding output (binyEs) / A,B coding output (binno) / Clip loose bag stepper motor pulse output (binyES) / A,B scale clip loose bag stepper motor pulse output (binno), clip loose bag stepper motor rotation direction signal (binyES), clip loose bag stepper motor rotation direction signal (binno)/ Loose bag (binyES) / Loose bag (binno) on scales A and B |