After-sales Service: | Following Updating |
---|---|
Warranty: | Under Discussion |
Switching Power Supply: | AC90~260V 50Hz(60Hz)Plus and Minus2% |
Still deciding? Get samples of US$ 650/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1.New algorithm, hardware system fully optimized, weighing control faster and more accurate; |
2.5-inch TFT LCD screen, full Chinese display, simplify the complexity, more comfortable to operate and use; |
3.High performance A/D conversion, sampling speed up to 960 times / sec; |
4.Standard dual-channel serial port, easier to interconnect the system; |
5.Comes with a USB interface, can be used to import and export all kinds of data, convenient for retaining important historical information or standardized settings for multiple devices; can also be used for product upgrades; |
6.Up to eight channels of signal input, twelve channels of digital control signal output, input and output port location can be customized to maximize the convenience of the user. |
General Specifications | Switching Power Supply | AC90~260V 50Hz(60Hz)±2% |
Operating Temperature | -10~40ºC | |
Maximum humidity | 90%R.H non-condensing | |
Protection Grade | Front panel IP65 | |
Power Consumption | Approx. 15W | |
Display and keypad | LCD display | Displays meter values, status and some recipe information |
Function keys | zero1:zero build, used for data zeroing | |
zero2:shortcut key to view, the interface corresponding to the number can enter the parameter content view and setup | ||
M:Menu key, administrators and system administrators can enter the setup parameter menu list. | ||
A/D conversion | A/D performance | 24-bit Sigma-Delta |
A/D conversion speed | 120/240/480/960 times/second adjustable | |
Non-linearity | 0.01%F.S | |
Gain Drift | 10PPM/°C | |
Input Sensitivity | 0.02μV/d | |
Input Range | 0.02~15mV | |
Maximum Display Accuracy | 1/100000 | |
Sensor power supply | DC5V 125mA(Max) | |
Input Impedance | 10MΩ | |
Zero Adjustment Range | 0.02~8mV (when sensor is 2mV/V) | |
I/O section | Inputs | 8 input ports, low level active |
Start/emergency stop/zero clear/alarm clear/recipe selection/pinch loose bag request/manual unloading/dual scale interlock inputs | ||
Outputs | 12 output ports, single drive current 500mA | |
Run/Stop/Fast Plus/Medium Plus/Slow Plus/Fixed Value/Pouch Clamping/Pouch Shooting/Alarm/Over and Under Difference/Batch Completion/Feeding/Upper and Lower Levels/Jog Stop |