specifications |
Power supply voltage V0 100-240 V AC 50/60 Hz |
V1 10-24V AC 50/60 Hz; 10-24V DC |
Consumption power V0 below 10W |
V1 AC: below 6 VA; DC: Below 5W |
The allowable voltage variation range is 90%~110% of the power supply voltage |
Insulation resistance ≥ 100M Ω (500V DC MEGA reference) |
Insulation strength 2000V AC (test conditions: 50/60Hz, 1 minute) |
Anti interference IEC61000-4-2 (electrostatic discharge), Class III |
IEC61000-4-4 (Electrical Fast Transient Pulse Group), Class III |
IEC61000-4-5 (surge), Class III |
Protection level IP65 (product front panel protection) (GB/T42-2008) |
Operating environment temperature -10~50 ºC (storage: -25~65 ºC) |
Environmental humidity of 35-85% R • H, no condensation |
Installation location indoor, height < 2000m |
Comparison output 2-point OC gate output, 100mA (MAX) |
Input specifications |
Sensor power supply B1 DC 10V ± 2%, 200mA (MAX) |
B2 DC 5V ± 2%, 100mA (MAX) |
Input impedance>10M Ω |
Conversion method Sigma Delta |
Measurement and control speed of 15 and 120 times/second (B6 series) |
240, 480, 960, 1920 times/second (B6F series) |
Nonlinear ± 0.05% F • S (measurement and control 15bps) |
(The higher the measurement and control speed, the worse the nonlinearity) |
Gain drift<10 ppm/ºC |
(When connecting sensors, matching terminal connectors must be used, otherwise it will deteriorate the temperature drift characteristics.) |
Maximum display accuracy of 1/100000 |
Input signal proportional measurement, equipped with a 4-wire strain sensor |
Contact input 1 external switch input, which can be used for clearing, peeling, allowing comparison output, etc |
Optional specifications |
Analog output A1 current output (4-20) mA, (0-10) mA, (0-20) mA photoelectric isolation, resolution: 1/12000, load capacity: 600 Ω |
A2 voltage output (1-5) V, (0-5) V |
A3 voltage output (0-10) V |
Communication interface S1 RS232 interface, Modbus RTU and TC ASCII protocol optoelectronic isolation |
Response time: 500 μ S (measured value) |
S2 RS485 interface, Modbus RTU and TC ASCII protocol |