≤ + 0.03 % Rdg./K
Non-linearity:
≤ 1.0 % F.S.
Relative hysteresis:
≤ 0.75 % F.S.
Non-repeatability with unchanged assembly position: ≤ 0.25 % F.S.
Deflection full scale:
approx. 60 µm
Mounting:
measuring range ≥ 0 ... 1000 N
there are three mounting holes on the lower side of the sensor,
equally spaced on T diameter with division 120°, one hole is
located directly across the cable exit. This kind of mounting is
allowed for compression load only.
Operating force max:
150 % of capacity
Dynamic load capacity: recommended 50 % of capacity
max.
70 % of capacity
Material:
stainless steel 1.4542
Electrical connection:
measuring range
shielded, TPE insulated cable with open
≤ 0 ... 500 N
ends for soldering, length appr. 2 m.
bending radius ≥ 20 mm
measuring range
additionally equipped with anti-kink protection
0 ... 1 kN to 0 .. 50 kN length appr. 40 mm,
bending radius ≥ 30 mm
measuring range
additionally equipped with anti-kink protection
≥ 0 ...100 kN
and adapter for cable holder,
length approx. 50 mm,
bending radius ≥ 30 mm
Protection class: acc. to EN 60529 range
≤ 0 ... 50 kN IP54
range
≥ 0 ... 100 kN IP65
Dimensions:
refer to table and dimensional drawing
General tolerance of dimensioning:
acc. to ISO 2768-f
Weight: depending on the measuring range, from 5 g up to 900 g
Wiring code:
measuring range ≤ 0 ... 50 N / ≥ 0 ...100 N
red / with excitation voltage
positive
black / brown excitation voltage
negative
green / green signal output
negative
white / yellow signal output
positive