Output Signal Type: | Digital Type |
---|---|
Production Process: | Normal Wirewound |
Material: | Stainless Steel |
Thread Type: | NPT, G1/4, 1/4-18NPT, M12, 7/16-20unf |
Wiring Type: | Four-Wire |
Measuring Medium: | Liquid |
Samples: |
---|
Suppliers with verified business licenses
Parameter | Min | Type | Max | Unit |
Digital Module Resolution | 60000 | Div | ||
Rated Load | 50.00(5000) | MPa | ||
Digital Refurbishing Frequency | 100 | /s | ||
Combined Error | ±0.25 | %FS | ||
Creep(30min) | ±0.10 | %FS | ||
Temperature effect | ±0.10 | %FS/10ºC | ||
Operating Temperature Range | -40 | 25 | 85 | ºC |
Storage Temperature Range | -20 | 25 | 55 | ºC |
Safe Overload | 120 | %FS | ||
Limit Overload | 200 | %FS | ||
Excitation voltage | 8 | 10 | 12 | VDC |
Power Dissipation | 0.5(10v) | W | ||
Communication connect | CAN | |||
Transmitting Distance | 500 | 1200 | m | |
Communication Fromat | CANopen2.0 | |||
Citation Standard | DB34/T 767-2008 |