After-sales Service: | Following Updating |
---|---|
Warranty: | Under Discussion |
Switching Power Supply: | DC24vplus and Minus5% |
Still deciding? Get samples of US$ 600/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1.Single meter and two scales, support up to three meters and six scales unloading interlock (without PLC ); |
2.Four analog voltage outputs for vibration plate charging, support voltage self-finding, self-correction; |
3.Supports a variety of unloading mechanisms: pneumatic, ordinary motor, stepper motor, etc; |
4.Two RS485 communication, support Modbus-RTU/ASCII and other protocols; |
5.Provide McgsPro touch screen program example source code for single/double/four/six scales; |
6.Supporting the functions of bag clamping, material level control, alarm of over and under difference, and under difference material replenishment; |
7.With dual-channel simultaneous packaging and automatic correction of the internal parameters of the module, greatly improving the rate of small packages, and realize the intelligence of the system; |
8.RS485 communication interface: connect PC, PLC, printer, label printer, remote display for remote reading and setting of the code printer or other external devices; |
9.10 input/20 output: used for start, stop, unloading, medium add/fast add, etc., switching function can be customized, convenient for various occasions of application; |
10.2 Sensor Interfaces: 2 6-wire analog sensor interfaces for weighing platforms, with a maximum of 8 350Ω sensors connected to a single channel; |
11.4 analog interfaces: 4 vibration plate voltage output interfaces, output range 0~5000mV. |
General Specification | Model | GBOX-802CD |
Switching Power Supply | DC24V±5% | |
Working Temperature | 0~40ºC | |
Maximum Humidity | 90%R.H non-condensing | |
Power Consumption | Approx. 3W | |
Calibration standard | Classlll6000e,1uV/d | |
Physical size | 213mm x 137mm x 38.5mm | |
Measurement Parameters | A/D conversion method | 24-bit Siqma-Delta |
Non-linear | 0.01%F.S | |
Gain drift | 10 PPM/°C | |
Input Sensitivity | 0.02μV/d | |
Input Range | 0.02~11mV (when sensor is 2mV/V) | |
Sensor power supply | DC5V, 125mA(Max) | |
Input Impedance | 10MΩ | |
Zero Adjustment Range | Maximum 0.02~8mV (when sensor is 2mV/V) | |
I/O Port | Sensor Interface | 2-way 6-wire analog sensor platform interface, single-channel connection of up to 8 350Ω sensors |
Switching interface | 10 in 20 out transistor input and output interface (of which OUT16-0UT19 for PWM output) | |
Communication interface | 2 RS485 communication interfaces 1 CAN bus interface (reserved function/customizable) |
|
Analog interface | 4-channel oscillator voltage output interface, output range 0~5000mV |