After-sales Service: | Following Updating |
---|---|
Warranty: | Under Discussion |
Switching Power Supply: | DC24V(18-36V) |
Still deciding? Get samples of US$ 600/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Hardware configuration | Stainless steel metal body with IP65 protection rating; |
Standard configuration | 1-way 6-wire sensor interface; |
1-way analog output interface; | |
1-way RS485 interface, 1-way RS232 interface with isolation; | |
in 4 out + 4 freely defined transistor input and output interfaces, i.e. up to 8 in or 8 out functions can be supported; | |
Optional | Rj45 standard network port or Profinet bus; |
1 analog output interface + 1 analog input interface (current/voltage optional); | |
Software function | A new generation of flow control algorithm, more stable flow rate. |
Support analog calibration, flow rate automatic/manual calibration | |
Traffic interference automatic locking and unlocking function | |
Support two network devices to access the instrument parameters at the same time function (ModubusTCP) | |
Work simulation:1,Loss-of-weight dosage mode; 2,Constant analog quantity mode; 3,Externally given mode |
|
Threshold anti-interference function, make the instrument work process more stable | |
Multi-material function, support up to 10 sets of material parameters, convenient for switching between different material parameters. |
General specifications | Switching power supply | DC24V(18-36V) |
Certified environment | -10~40ºC, 90%R.H non-condensing | |
Operating environment | -20~40ºC, 90%R.H non-condensation | |
Storage environment | -40~60ºC;90%R.H non-condensing | |
Maximum power consumption | 15W | |
Certification standard | Classll, 6000e, 1uV/e | |
Enclosure Dimension | 62mmx134mmx128mm | |
Product weight | Approx. 880g | |
Measuring parameters | Excitation Voltage | 5V 200mA(MAX) |
Load Cell Requirements | 1 analog platform interface, 6-wire with long wire compensation, up to 8 350Q load cells, supports 1mV/V, 2mV/V, 3mV/V sensitivity. | |
Input Range | 0~15mV | |
Input Sensitivity | 0.1uV/d | |
Non-linearity | 0.01%FS | |
A/D conversion speed | 480 times/sec | |
Maximum display accuracy | 1/1,000,000 | |
Communication/Control Interface | Standard | 1 channel 232 interface + 1 channel 485 interface with isolation 1 analog output 4 in 4 out + 4 freely defined transistor input and output interfaces, i.e. up to support 8 in or 8 out functions |
Options | Rj45 standard network port or Profinet bus. 1 analog output + 1 analog input (current/voltage selectable). |