After-sales Service: | Following Updating |
---|---|
Warranty: | Under Discussion |
Installation: | General Installation Meter |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
characteristic | Can display the input voltage and current value, relay output / analog output / RS485 output, choose one of three |
definition | ±0.2%FS ±1Counts |
indication range | High brightness red LED4 digits =0~9999 Counts, the ratio can be changed |
input range | Current 10A, voltage 600V |
Applicable frequency | 45Hz ~65Hz. |
Digital output capability | Using the RS-485 output, transmission speed, 9600.19200 |
Output protection | Open open or short circuit |
Pressure resistance capacity | AC2KV / 1 min, between input / power / housing, AC16KV / 1 min between input / output / power / housing. |
Long-term stability | Annual drift degree of 0.2% |
temperature coefficient | ≤100ppm/°C From 0~60°C; ≤50ppm/25°C±5°C |
service environment | 0 °C to + 60 °C 20 to 90% RH without condensation. |
Storage conditions | -10°C~ + 70 °C 20 ~ 90% RH without condensation |
working power supply | AC/DC85~265V |
Case material | Non-combustible ABS ejection molding |
Dimensions / installation mode | Disk fixed type. The 96X96X80mm (depth) disk surface is fixed.72X72X80mm (depth) opening size: 68X68mm. |
Operating procedures | |||
1- 1 | 111.1 | Normal display | Press M ,display [ dot], setting dot |
1-2 | dot | Setting dot | Press M ,display [0.0], select dot |
1-3 | 0.0 | Select dot | Range [0./0.0/0.00/0.000] / press M ,save setting. Then display [ dSH] |
1-4 | dSH | Setting Input Hi | Press M ,display [100.0], select input high limit value |
1- 5 | 100.0 | Select Input Hi value | Range [- 1999~9999] / Press M ,save setting. Then display [ dSL] |
1-6 | dSL | Setting Input lo | Press M ,display [000.0], select input low limit value |
1-7 | 000.0 | Select Input lo value | Input Range [- 1999~9999] / Press M ,save setting. Then display [LCUt] |
1-8 | LCUt | Setting Mask | Press M ,display [000.0], select mask |
1-9 | 000.0 | Select Mask value | Range [- 1999~9999] / Press M ,save setting. Then display [AvG] |
1- 10 | AvG | Setting Average | Press M ,display [000.0], select average times |
1- 11 | 01 | Select average times | Range [01~99] / Press M ,save setting. Then display [dFiT] |
1- 12 | dFit | Setting Filter | Press M ,display [000.0],select filter |
1- 13 | 00 | Select Filter | Range [00~99] / Press M ,save setting. Then display [CodE] |
1- 14 | CodE | Setting Code | Press M ,display[0000], select code. |
1- 15 | 0000 | Select Code | Input [0095], restore factory settings after Press M Input [0020] / Press M ,display [ZEro], setting adjust Input lo Input [0021] / Press M ,display[SPAn], setting adjust Input Hi Input other value / Press M ,display [111.1] (Normal display) |
2- 1 | ZEro | Setting adjust Input lo | Press M ,display [000.0] , select adjust Input lo |
2-2 | 000.0 | Select adjust Input lo | Input Range [- 1999~9999] / Press M ,save setting. Then display [111.1] |
3- 1 | SPAn | Setting adjust Input Hi | Press M ,display [000.0], select adjust Input Hi |
3-2 | 000.0 | Select adjust Input Hi | Input Range [- 1999~9999] / Press M ,save setting. Then display [111.1] |