After-sales Service: | Following Updating |
---|---|
Warranty: | Under Discussion |
Weight: | 2.5kg |
Still deciding? Get samples of US$ 500/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1.Membrane amperometric measurement principle, using the overlay method of three electrode type constant current measurement system, applicable to a variety of water quality conditions, can withstand surfactant components; |
2.Adoption of single-chip computer control, menu operation, convenient and simple; |
3.It can measure the residual chlorine value and temperature value, or total chlorine value and temperature value of water samples; |
4.With automatic temperature compensation function, support DPD method comparison calibration; |
5. Isolated output (4~20)mA DC signal, upper and lower output limits can be adjusted steplessly; |
6. Isolated (RS-485) digital signal output; |
7.With automatic upper and lower limit alarm function; |
8.With data retention function, i.e., when the instrument is doing other work such as auto-cleaning function, the original measurement data will be kept on the display, and the new measurement data will be displayed after the instrument resumes the normal measurement state; |
9.With storage and query function, it can store 2000 sets of measurement data; |
10. Plate-mounted or wall-mounted installation is available, which is convenient for installation, operation and maintenance. |
Model | SJG-792A | ||
Residual chlorine | Total Chlorine | Chlorine Dioxide | |
Measuring range (Two specifications are available) |
(0.000~2.000)mg/L (0.05~20.00)mg/L |
(0.000 to 2.000)mg/L (0.05~20.00)mg/L |
(0.000~2.000)mg/L (0.05~20.00)mg/L |
Resolution | 0.01mg/L | 0.01mg/L | 0.01mg/L |
Measurement Accuracy | Within 4mg/L, the error is <1%; within 16mg/L, the error is <3%. | Within 4mg/L, the error is <1%; within 16mg/L, the error is <3%. | Within 4mg/L, the error is <1%; within 16mg/L, the error is <3%. |
Sample flow rate | 15-30L/H | 15-30L/H | 15-30L/H |
pH range | 4~9pH | 4~12pH | 1-12pH |
Electrode size | Diameter approx. 25mm; Length approx. 205mm | Diameter approx. 25mm; Length approx. 205mm | - |
Operating Temperature | 0 ~ 45ºC (non-condensing in water) | 0 ~ 45ºC (non-condensing in water) | 0 ~ 50ºC (non-condensing in water) |
Set configuration | SJG-792A host 1, Germany imported residual chlorine sensor 1, 1 cable 5 meters, measurement of the flow of pool 1 set | SJG-792A mainframe 1 unit, Germany imported total chlorine sensor 1 unit, 1 cable 5 meters, measuring flow cell 1 set | SJG-792A mainframe 1 unit, Germany imported chlorine dioxide sensor 1 unit, 1 cable 5 meters, measuring flow cell 1 set |
Others | The first running time is about 2 hours Response time after normal operation T90 about 2 minutes |
First running time about 2 hours Response time after normal operation T90 about 3 minutes (salt water about 5 minutes) |
First run time approx. 1 hour Response time after normal operation T90 approx. 1 min. 30 sec. |
Flow cell inlet and outlet pipe diameter | 1/4" quick plug | ||
Power supply | AC (220±22)V, (50±1)Hz; or DC 24V | ||
Instrument protection grade | IP65 | ||
Dimensions (mm), Weight (kg) | 166×166×110,2.5 | ||
Opening size (mm) | 138×138 |